Research Article
Optimal Matching of Ring and Radial Wiring Modes with Three-Level Feeder Automation Configuration in 10 kV Urban Distribution Networks Based on Graph Attention Networks
@ARTICLE{10.4108/ew.14640, author={Fei Zheng and Jinseng Liu and Ning Luo and Qingyu Zhao and Mao Miao}, title={Optimal Matching of Ring and Radial Wiring Modes with Three-Level Feeder Automation Configuration in 10 kV Urban Distribution Networks Based on Graph Attention Networks}, journal={EAI Endorsed Transactions on Energy Web}, volume={13}, number={1}, publisher={EAI}, journal_a={EW}, year={2026}, month={10}, keywords={Graph Attention Network, Distribution Network Wiring Mode, Feeder Automation Configuration, ICT Feasibility Constraint}, doi={10.4108/ew.14640} }- Fei Zheng
Jinseng Liu
Ning Luo
Qingyu Zhao
Mao Miao
Year: 2026
Optimal Matching of Ring and Radial Wiring Modes with Three-Level Feeder Automation Configuration in 10 kV Urban Distribution Networks Based on Graph Attention Networks
EW
EAI
DOI: 10.4108/ew.14640
Abstract
The matching between wiring modes and feeder automation (FA) levels in 10 kV urban distribution networks lacks systematic methods, particularly neglecting communication infrastructure constraints. This paper proposes a two-stage matching model based on graph attention networks (GAT) that fuses electrical, topological, and information and communication technology (ICT) features. A 360-scenario dataset is constructed from IEEE 33/69-node test systems, covering four wiring modes (single-radial, multi-section radial, two-supply ring, three-supply ring) and three FA levels (FA-I/II/III). The first stage employs GAT for wiring mode identification, achieving 91.7% accuracy. The second stage recommends optimal FA configurations through feature fusion with embedded ICT feasibility hard constraints, attaining 83.3% Top-1 matching accuracy. Transfer validation on 72 operational feeders from three Nanjing districts yields 87.5% wiring mode accuracy and 79.2% Top-1 FA matching. Communication features contribute a 3.1 percentage-point gain to matching accuracy, and the constraint mechanism effectively prevents infeasible FA recommendations in low-coverage scenarios. Ablation studies confirm the superiority of the two-stage cascaded architecture over end-to-end alternatives.
Copyright © 2026 Fei Zheng et al., licensed to EAI. This is an open access article distributed under the terms of the CC BY-NC-SA 4.0, which permits copying, redistributing, remixing, transformation, and building upon the material in any medium so long as the original work is properly cited.