About | Contact Us | Register | Login
ProceedingsSeriesJournalsSearchEAI
ew 18(16): e1

Research Article

Stabilization of Electrical Parameters of Machine-Converter Voltage Source

Download1319 downloads
Cite
BibTeX Plain Text
  • @ARTICLE{10.4108/eai.30-1-2018.153813,
        author={Yu. N. Dementyev and A. V. Glazachev and K. N. Negodin and I. Vajda and V. I. Susdorf},
        title={Stabilization of Electrical Parameters of Machine-Converter Voltage Source},
        journal={EAI Endorsed Transactions on Energy Web and Information Technologies},
        volume={5},
        number={16},
        publisher={EAI},
        journal_a={EW},
        year={2018},
        month={1},
        keywords={Machine-converter sources, synchronous generator, armature winding, asynchronous exciter, PWM autonomous inverter, cycloconverter, voltage, frequency.},
        doi={10.4108/eai.30-1-2018.153813}
    }
    
  • Yu. N. Dementyev
    A. V. Glazachev
    K. N. Negodin
    I. Vajda
    V. I. Susdorf
    Year: 2018
    Stabilization of Electrical Parameters of Machine-Converter Voltage Source
    EW
    EAI
    DOI: 10.4108/eai.30-1-2018.153813
Yu. N. Dementyev1,*, A. V. Glazachev1, K. N. Negodin1, I. Vajda1,2, V. I. Susdorf3,4
  • 1: Tomsk Polytechnic University, School of Energy & Power Engineering, av. Lenina, 30, 634050, Tomsk, Russian Federation
  • 2: Obuda University, Kando Kalman Polytechnic, Becsi ut 96/B, 1034, Budapest, Hungary
  • 3: Komsomolsk-na-Amure State Technical University, Electric Drive and Automation of Industrial Installations, av. Lenina, 27,
  • 4: 681013, Komsomolsk-na-Amure, Russian Federation
*Contact email: dementev@tpu.ru

Abstract

The paper is devoted to development of Machine-Converter Source (MCS), which forms the output voltage waveform of electric generator as sum of EMFs with near frequencies. As electric modulation generator is used a synchronous generator and asynchronous exciter that have both common driving shaft and common housing. We studied the automatic control systems for output electrical parameters of MCS when changing speed of driving shaft and load power in wide ranges.

Keywords
Machine-converter sources, synchronous generator, armature winding, asynchronous exciter, PWM autonomous inverter, cycloconverter, voltage, frequency.
Received
2017-12-01
Accepted
2018-01-21
Published
2018-01-30
Publisher
EAI
http://dx.doi.org/10.4108/eai.30-1-2018.153813

Copyright © 2018 Yu. N. Dementyev et al., licensed to EAI. This is an open access article distributed under the terms of the Creative Commons Attribution licence (http://creativecommons.org/licenses/by/3.0/), which permits unlimited use, distribution and reproduction in any medium so long as the original work is properly cited.

EBSCOProQuestDBLPDOAJPortico
EAI Logo

About EAI

  • Who We Are
  • Leadership
  • Research Areas
  • Partners
  • Media Center

Community

  • Membership
  • Conference
  • Recognition
  • Sponsor Us

Publish with EAI

  • Publishing
  • Journals
  • Proceedings
  • Books
  • EUDL