About | Contact Us | Register | Login
ProceedingsSeriesJournalsSearchEAI
Proceedings of the 1st International Multi-Disciplinary Conference Theme: Sustainable Development and Smart Planning, IMDC-SDSP 2020, Cyperspace, 28-30 June 2020

Research Article

Non-uniform distributed shunt admittance Used As Broadband Termination

Download625 downloads
Cite
BibTeX Plain Text
  • @INPROCEEDINGS{10.4108/eai.28-6-2020.2298153,
        author={Mounir  Belattar and Lashab  Mohamed and Raed  Abd-Alhameed},
        title={ Non-uniform distributed shunt admittance Used As Broadband Termination },
        proceedings={Proceedings of the 1st International Multi-Disciplinary Conference Theme: Sustainable Development and Smart Planning, IMDC-SDSP 2020, Cyperspace, 28-30 June 2020},
        publisher={EAI},
        proceedings_a={IMDC-SDSP},
        year={2020},
        month={9},
        keywords={distributed shunt capacitance effective length local wavelength nonuniform transmission line physical length},
        doi={10.4108/eai.28-6-2020.2298153}
    }
    
  • Mounir Belattar
    Lashab Mohamed
    Raed Abd-Alhameed
    Year: 2020
    Non-uniform distributed shunt admittance Used As Broadband Termination
    IMDC-SDSP
    EAI
    DOI: 10.4108/eai.28-6-2020.2298153
Mounir Belattar1,*, Lashab Mohamed2, Raed Abd-Alhameed3
  • 1: Departement of Electrical Engineering, 20 Aout 1955 University of Skikda, Algeria
  • 2: Departement of Electrical Engineering, Larbi Ben M’hidi University of Oum El Bouaghi, Algeria
  • 3: Electronics, Communications and Information Systems Engineering Research Group (ECISE RG), Bradford University
*Contact email: mounir.belattar@yahoo.com

Abstract

Broadband microwave termination is made of a uniform transmission line terminated by a nonuniform transmission having a varied distributed shunt admittance. We assume a line in which the fractional rise in admittance per wavelength is constant. By means of a nonuniform transmission line having a fixed geometrical length, we can obtain an arbitrarily large effective length without destroying the match of the input.

Keywords
distributed shunt capacitance effective length local wavelength nonuniform transmission line physical length
Published
2020-09-03
Publisher
EAI
http://dx.doi.org/10.4108/eai.28-6-2020.2298153
Copyright © 2020–2025 EAI
EBSCOProQuestDBLPDOAJPortico
EAI Logo

About EAI

  • Who We Are
  • Leadership
  • Research Areas
  • Partners
  • Media Center

Community

  • Membership
  • Conference
  • Recognition
  • Sponsor Us

Publish with EAI

  • Publishing
  • Journals
  • Proceedings
  • Books
  • EUDL