Proceedings of the 1st Workshop on Multidisciplinary and Its Applications Part 1, WMA-01 2018, 19-20 January 2018, Aceh, Indonesia

Research Article

Analysis of Automatically Switched Optical Network (ASON) Protection System in Jakarta – Bogor Fiber-Optic Transmission Link

Download1270 downloads
  • @INPROCEEDINGS{10.4108/eai.20-1-2018.2281861,
        author={Dika Fadilah  Abduhuu and Peby Wahyu  Purnawan},
        title={Analysis of Automatically Switched Optical Network (ASON) Protection System in Jakarta -- Bogor Fiber-Optic Transmission Link},
        proceedings={Proceedings of the 1st Workshop on Multidisciplinary and Its Applications Part 1, WMA-01 2018, 19-20 January 2018, Aceh, Indonesia},
        publisher={EAI},
        proceedings_a={WMA-1},
        year={2019},
        month={9},
        keywords={protection system sdh wdm msp sncp ason},
        doi={10.4108/eai.20-1-2018.2281861}
    }
    
  • Dika Fadilah Abduhuu
    Peby Wahyu Purnawan
    Year: 2019
    Analysis of Automatically Switched Optical Network (ASON) Protection System in Jakarta – Bogor Fiber-Optic Transmission Link
    WMA-1
    EAI
    DOI: 10.4108/eai.20-1-2018.2281861
Dika Fadilah Abduhuu1,*, Peby Wahyu Purnawan1
  • 1: Faculty of Engineering Universitas Budi Luhur
*Contact email: dika.fadilah@gmail.com

Abstract

The use of protection on fiber-optic network was to prevent the possibility of failures it was required reliable protection system to keep the service running. The process to find appropriate protection systems on Synchronous Digital Hierarchy (SDH) and Wavelength Division Multiplexing (WDM) networks was based on traffic distribution capacity, network topology, and economic considerations. There were several types of protection: Multiplex Section Protection (MSP), Sub-Network Connection Protection (SNCP), and Automatically Switched Optical Network (ASON). The protection system discussed in this thesis was Automatically Switched Optical Network (ASON) used by Mora Telematika Indonesia Inc. The test results and analysis conducted on the main line and ASON protection were revealed that ASON protection quality which able to handle multiple fault so that the traffic automatically moved to the protection line via Depok = 15.1324 ms, via Graha = 26.6358 ms, and via BSD = 49.6828 ms; in accordance with standardization of Service Level Agreement (SLA) with switching time provider <50 ms which was in the same quality between throughput, frame loss, jitter and the main line. Thus ASON protection kept the traffic running normally.