The Design of Wireless Portable Electrocardiograph Monitoring System Based on ZigBee

Download1864 downloads
Cite
BibTeX Plain Text
  • @ARTICLE{10.4108/eai.13-7-2018.164558,
        author={Saleemullah Memon and Kamlesh Kumar Soothar and Kamran Ali Memon and Arif Hussain Magsi and Asif Ali Laghari and Muhammad Abbas and Noor ul Ain},
        title={The Design of Wireless Portable Electrocardiograph Monitoring System Based on ZigBee},
        journal={EAI Endorsed Transactions on Scalable Information Systems},
        volume={7},
        number={28},
        publisher={EAI},
        journal_a={SIS},
        year={2020},
        month={5},
        keywords={ECG monitoring system, AD8232, Arduino UNO R3, ZigBee},
        doi={10.4108/eai.13-7-2018.164558}
    }
    
  • Saleemullah Memon
    Kamlesh Kumar Soothar
    Kamran Ali Memon
    Arif Hussain Magsi
    Asif Ali Laghari
    Muhammad Abbas
    Noor ul Ain
    Year: 2020
    The Design of Wireless Portable Electrocardiograph Monitoring System Based on ZigBee
    SIS
    EAI
    DOI: 10.4108/eai.13-7-2018.164558
Saleemullah Memon1, Kamlesh Kumar Soothar2, Kamran Ali Memon1,*, Arif Hussain Magsi3, Asif Ali Laghari4, Muhammad Abbas3, Noor ul Ain2
  • 1: School of Electronic Engineering, Beijing University of Posts & Telecommunications, Beijing, China
  • 2: School of Information & Communication Engineering, Beijing University of Posts & Telecommunications, Beijing, China
  • 3: School of Computer Science, Beijing University of Posts and Telecommunications Beijing, China
  • 4: Sindh Madressatul Islam University, Karachi, Pakistan
*Contact email: Ali.kamran77@gmail.com

Abstract

The emerging trend in wireless hospitals requires the development of bio-signal acquisition devices to be easily integrated into a single clinical routine. The wired devices used in hospitals and clinics, which makes setup very inconvenient, costly, and difficult to manage patients. It is crucial to develop and design a clinical diagnostic system that takes bio-signal from the body of the patient and transmits wirelessly to the physicians/hospital. In this paper, we have designed a novel portable system for ECG signal acquisition, processing, and wireless transmission using a ZigBee module. Our portable design enhances mobility, small in size, and very cheap for long term monitoring of cardiac patients. The results show that the ECG wave successfully transmitted to the physician, and heartbeat values are visible to the patient. Furthermore, the results of the ECG wave are unclear when the position of electrodes is dislocated.

Keywords
ECG monitoring system, AD8232, Arduino UNO R3, ZigBee
Received
2020-04-04
Accepted
2020-05-09
Published
2020-05-14
Publisher
EAI
http://dx.doi.org/10.4108/eai.13-7-2018.164558

Copyright © 2020 Saleemullah Memon et al., licensed to EAI. This is an open access article distributed under the terms of the Creative Commons Attribution license (http://creativecommons.org/licenses/by/3.0/), which permits unlimited use, distribution, and reproduction in any medium so long as the original work is properly cited.

EBSCOProQuestDBLPDOAJPortico
EAI Logo

About EAI

  • Who We Are
  • Leadership
  • Research Areas
  • Partners
  • Media Center

Community

  • Membership
  • Conference
  • Recognition
  • Sponsor Us

Publish with EAI

  • Publishing
  • Journals
  • Proceedings
  • Books
  • EUDL