About | Contact Us | Register | Login
ProceedingsSeriesJournalsSearchEAI
sumare 26(4):

Research Article

Evaluating the Impact of Integrated Reflective Louver Daylighting and LED Dimming Control Systems on Visual Comfort and Cognitive Performance in Office Environments

Download38 downloads
Cite
BibTeX Plain Text
  • @ARTICLE{10.4108/eetsmre.11241,
        author={Quan-Truong Vuong},
        title={Evaluating the Impact of Integrated Reflective Louver Daylighting and LED Dimming Control Systems on Visual Comfort and Cognitive Performance in Office Environments},
        journal={EAI Endorsed Transactions on Sustainable Manufacturing and Renewable Energy},
        volume={2},
        number={4},
        publisher={EAI},
        journal_a={SUMARE},
        year={2026},
        month={1},
        keywords={Visual Comfort, DGP, Cognitive Performance, Zero-Energy Buildings, Daylighting Louvers, LED Dimming Control},
        doi={10.4108/eetsmre.11241}
    }
    
  • Quan-Truong Vuong
    Year: 2026
    Evaluating the Impact of Integrated Reflective Louver Daylighting and LED Dimming Control Systems on Visual Comfort and Cognitive Performance in Office Environments
    SUMARE
    EAI
    DOI: 10.4108/eetsmre.11241
Quan-Truong Vuong1,2,*
  • 1: Ho Chi Minh City University of Technology
  • 2: Vietnam National University Ho Chi Minh City
*Contact email: vqtruong.sdh241@hcmut.edu.vn

Abstract

The drive towards Zero-Energy Buildings (ZEB) necessitates optimized lighting energy solutions. Integrated technologies combining daylight-concentrating louvers and LED Dimming Control have been shown to significantly reduce energy consumption. However, the impact of these dynamic lighting changes on occupants' visual comfort and work performance remains a research gap. This study aims to evaluate the balance between energy efficiency and occupant comfort by integrating the Daylight Glare Probability (DGP) into the control algorithm. Three lighting scenarios were tested in a simulated office mock-up: A (Baseline: LED ON/OFF), B (Energy Optimization: Dimming based on average illuminance), and C (Comfort Optimization: Dimming based on both illuminance and DGP<0.35). The results demonstrate that Scenario C achieved an average energy saving of 75.7% compared to Scenario A, while successfully maintaining the Daylight Glare Probability (DGP) at an acceptable level (DGP≤0.35). Crucially, Scenario C resulted in an 8.1% faster cognitive reaction time and 50% fewer errors compared to Scenario B, proving that a comfort-prioritized control strategy not only saves energy but also enhances cognitive performance. The study proposes a dual-factor (Illuminance, DGP) control model as the sustainable operational standard for future ZEB lighting systems.

Keywords
Visual Comfort, DGP, Cognitive Performance, Zero-Energy Buildings, Daylighting Louvers, LED Dimming Control
Received
2025-12-05
Accepted
2026-01-18
Published
2026-01-20
Publisher
EAI
http://dx.doi.org/10.4108/eetsmre.11241

Copyright © 2026 Vuong-Quan Truong et al., licensed to EAI. This is an open access article distributed under the terms of the CC BYNC-SA 4.0, which permits copying, redistributing, remixing, transformation, and building upon the material in any medium so long as the original work is properly cited.