        author={Hangxu Su and Lvming Lv and Xufen Xie and Miao Miao},
        title={Study on Detection of Vascular Inner Wall with IVUS Image},
        proceedings={Wireless and Satellite Systems. 13th EAI International Conference, WiSATS 2022, Virtual Event, Singapore, March 12-13, 2023, Proceedings},
        proceedings_a={WISATS},
        year={2023},
        month={6},
        keywords={IVUS SVC False color enhancement Detection of blood vessel lining},
        doi={10.1007/978-3-031-34851-8_2}
    }
    
  • Hangxu Su
    Lvming Lv
    Xufen Xie
    Miao Miao
    Year: 2023
    Study on Detection of Vascular Inner Wall with IVUS Image
    WISATS
    Springer
    DOI: 10.1007/978-3-031-34851-8_2
Hangxu Su1, Lvming Lv1, Xufen Xie1, Miao Miao1,*
  • 1: School of Information Science and Engineering, Dalian Polytechnic University, NO. 1 Qinggongyuan, Ganjingzi District
*Contact email: miaomiao@dlpu.edu.cn

Abstract

Images obtained by Intravascular ultrasound (IVUS) technology play a key role in detecting the lining of blood vessels. However, IVUS images are not clear enough usually, it is difficult to detect the inner wall of the blood vessels. It further affects the diagnosis results. In view of this situation, we first applies the pseudo-color enhancement algorithm to enhance the image; Second, the images were dichotomized by Support Vector Classification (SVC), and the images were divided into internal and external parts; then Hough gradient transform based on Canny operator is applied to detect the inner wall of blood vessels. The proposed method was applied to detect 100 frames of IVUS images and compared with the actual judgment results of doctors. The detection results showed that the detection results of blood vessel lining in 97 frames were consistent with the doctors’ judgment results, and the detection accuracy could reach 97%. Experimental results show that the method can effectively highlight the characteristics of the inner wall of blood vessels and detect the inner wall of blood vessels. It can greatly improve the diagnostic accuracy in the actual medical process.

Keywords
IVUS SVC False color enhancement Detection of blood vessel lining
Published
2023-06-03
Appears in
SpringerLink
http://dx.doi.org/10.1007/978-3-031-34851-8_2
Copyright © 2023–2025 ICST
EBSCOProQuestDBLPDOAJPortico
EAI Logo

About EAI

  • Who We Are
  • Leadership
  • Research Areas
  • Partners
  • Media Center

Community

  • Membership
  • Conference
  • Recognition
  • Sponsor Us

Publish with EAI

  • Publishing
  • Journals
  • Proceedings
  • Books
  • EUDL